logo
Casa. > prodotti >
Analisatore di qualità dell'acqua
>
DX-DO3000 Industrial-Grade DO Analyzer Dependable Oxygen Monitoring Solution for a Variety of Monitoring Needs

DX-DO3000 Industrial-Grade DO Analyzer Dependable Oxygen Monitoring Solution for a Variety of Monitoring Needs

Dettagli del prodotto:
Place of Origin: China
Marca: Wuxi Daoxin Technology Co., Ltd.
Certificazione: CE,CCC
Model Number: DX-DO3000
Informazioni dettagliate
Place of Origin:
China
Marca:
Wuxi Daoxin Technology Co., Ltd.
Certificazione:
CE,CCC
Model Number:
DX-DO3000
Principio di misura:
Membrana Luminescente O Polarografica (Metodo a Membrana)
Gamma della compensazione di temperatura:
0 80 °C (compensazione automatica o manuale)
Precisione di misura:
±1% FS o ±0,1 mg/L
Intervallo di misurazione:
0-20 mg/L (Intervalli multipli opzionali)
Sottoscrizione del segnale:
4-20mA, RS485 (Modbus RTU)
Tempo di risposta:
≤ 10 s (secundi)
Durata di vita del sensore:
Metodo di fluorescenza: ≥ 2 anni (senza perdita della membrana); Metodo a membrana: da 6 a 12 mesi (
Funzione di allarme:
Alarme di alta/bassa frequenza / uscita del relè
Evidenziare:

High Light

Evidenziare:

DO Analyzer

,

Industrial Grade DO Analyzer

,

Diver Oxygen Monitoring Needs DO Analyzer

Informazioni di trading
Minimum Order Quantity:
1
Packaging Details:
carton
Delivery Time:
2-5 work days
Payment Terms:
T/T, L/C, Western Union
Supply Ability:
100+set+5
Descrizione del prodotto
DX-DO3000 Industrial-Grade DO Analyzer
Dependable Oxygen Monitoring Solution for a Variety of Monitoring Needs
Key Specifications
Measurement Principle Luminescent Or Polarographic Membrane (Membrane Method)
Temperature Compensation Range 0 ~ 80 ℃ (Automatic Or Manual Compensation)
Measurement Accuracy ±1% FS Or ±0.1 Mg/L
Measurement Range 0-20 Mg/L (Multiple Ranges Optional)
Signal Output 4-20mA, RS485 (Modbus RTU)
Response Time ≤ 10s (Seconds)
Sensor Lifespan Fluorescence Method: ≥ 2 Years (no Membrane Loss); Membrane Method: 6 To 12 Months (requires Regular Maintenance)
Alarm Function Hi/Low Alarm / Relay Output
Product Overview

The DX-DO3000 Online Dissolved Oxygen Meter, developed by Wuxi Daoxin Technology, is a powerful and dependable tool for continuous DO monitoring in complex industrial environments. It integrates advanced optical luminescent sensing technology, ensuring stable and drift-free measurement without the need for regular membrane replacement or electrolyte refilling.

Designed for versatility, the DX-DO3000 offers two sensor options:

  • Maintenance-free fluorescence sensor - Ideal for wastewater and aquaculture applications
  • Polarographic membrane sensor - Suited for controlled laboratory or bioprocessing environments

Both variants support high-resolution detection (0.01 mg/L) and deliver rapid response times of less than 10 seconds, ensuring accurate feedback in dynamic systems.

The analyzer features a wide temperature compensation range from 0°C to 80°C, with automatic or manual calibration options. Its rugged 316L stainless steel construction offers excellent resistance to corrosion, scaling, and environmental contaminants, extending the lifespan of the sensor in aggressive applications.

Output options include 4-20mA current loop and RS485 Modbus RTU communication, making integration into centralized control systems simple and effective. The device supports AC220V or DC24V power input, suitable for both fixed and mobile monitoring setups.

Installation is flexible with wall-mount, immersion, or flow-through configurations available. Optional self-cleaning devices and anti-fouling sensor shields can be integrated to further reduce maintenance efforts in high-biofilm environments.

Technical Parameters
Operating Temperature -10 ~ 60 ℃
Signal Output 4-20mA, RS485 (Modbus RTU)
Sensor Lifespan Fluorescence Method: ≥ 2 Years (no Membrane Loss); Membrane Method: 6 To 12 Months (requires Regular Maintenance)
Measurement Accuracy ±1% FS Or ±0.1 Mg/L
Measurement Range 0-20 Mg/L (Multiple Ranges Optional)
Measurement Principle Luminescent Or Polarographic Membrane (Membrane Method)
Response Time ≤ 10s (Seconds)
Installation Immersion / Flow-through (Flange Option)
Flow Velocity ≥ 0.2 M/s (flow Required For Membrane Method; Still Water Available For Fluorescence Method)
Sensor Type Fluorescence Method: No Membrane, Resistant To Contamination; Membrane Method: Replaceable Diaphragm (electrolyte Required)
Applications
Wastewater Treatment

Controls aeration efficiency in biological tanks and oxidation ditches, optimizing energy usage while improving pollutant removal.

Aquaculture

Provides stable DO monitoring crucial for fish and shrimp health in high-density farming systems.

Pharmaceutical & Biotech

Vital for fermentation and enzymatic reactions, ensuring product quality and biological efficiency.

Breweries

Tightly controls oxygen during fermentation and bottling stages to prevent oxidation and spoilage.

Environmental Research

Supports dissolved oxygen profiling in rivers, reservoirs, and lakes for ecological assessments.

Industrial Water Management

Maintains oxygen levels in power plants and cooling systems to prevent corrosion or anaerobic activity.

Support & Services

Wuxi Daoxin Technology provides a full spectrum of support services to ensure users gain the maximum value from their DX-DO3000 system.

  • Complete documentation including installation manuals, wiring schematics, and Modbus communication guides
  • Installation assistance and system commissioning guidance available remotely or on-site
  • Real-time troubleshooting through multiple channels including email, hotline, and remote desktop support
  • Replacement parts inventory including sensor caps, cables, cleaning accessories, and calibration solutions
  • Annual maintenance packages with performance recalibration services and operational training